IN BRIEF
750VA line interactive, 500W extended-run tower UPS for networks
Maintains user selecable sine-wave 120, 110 or 100V nominal output
Simultaneous communications via SNMPWEBCARD slot, DB9 serial and HID enabled USB ports
Input: NEMA 5-15P (120V 15A) / Output: 8 NEMA 5-15R (120V)
SYSTEM OVERVIEW
Voltage compatibility: 120V (110, 100V user selectable)
Frequency compatibility: 60 Hz
OUTPUT
Output VA: 750
Output watts: 500
Output nominal voltage: 120, 110, 100V AC
Output voltage regulation :
LINE MODE: Sine wave line voltage 120V (+6%, -10%), 110V (+6%, -10%), 100V (+6%, -10%),
BATTERY MODE: Sine wave output 120V, 110V, 100V (+/-5%)
Output frequency regulation
LINE MODE: Passes line frequency of +/-10%
BATTERY MODE: Inverter output regulated to 60Hz (+/- 1Hz)
Outlet quantity / type: 8 NEMA 5-15R
INPUT
Maximum input amps: 5.4A (120V), 5.8A (110V), 6.4A (100V)
Input connection type: NEMA 5-15P
Input cord length: 6 ft.
Recommended Electrical Service: 120V 15A
BATTERY
Full load runtime: 10 minutes (500w) expandable
Half load runtime: 27 minutes (250w) expandable
Expandable battery runtime: Runtime is expandable with BP24V28-2U (limit 1) or BP24V70-3U (multi-pack compatible)
DC system voltage: 24VDC
Battery recharge rate: 4.5 hour recharge to 90% (max)
Replacement Battery Cartridge: RBC24-SLT
VOLTAGE REGULATION
Voltage regulation description: Automatic Voltage Regulation (AVR) circuits maintain clean, regulated computer-grade 120, 110, 100V nominal output, without using battery power, during brownouts 95V (120V), 87V (110V), 83V (100V)
Overvoltage correction : Input voltages between 127 and 145V (120V), 116 and 133 (110V), 111 and 121 (100V) are reduced by 12%
Brownout correction: Input voltages between 95 and 108 (120V), 87 and 99 (110V), 83 and 93 (100V) are boosted by 14%
LEDS ALARMS & SWITCHES
Front panel LEDs: Includes front panel LEDs to indicate line / battery power status, over / under voltage correction, battery charge level, load percentage, overload, wiring fault and replace battery.
Alarms: Audible alarm warns of power failure condition
Switches: Includes two pushbutton switches for on/off power control and self-test/ alarm cancel functions. Also includes two dipswitch controls for setting the nominal voltage
SURGE / NOISE SUPPRESSION
AC surge suppression: 570 joules
AC suppression response time: Instantaneous
Dataline suppression: Includes 8-wire RJ45 jack; pins 1, 2, 3 and 6 provide 10baseT Ethernet line surge suppression with 7.5V clamping; pins 4 and 5 provide single-line tel/DSL line surge suppression starting at 260V
EMI / RFI AC noise suppression: Yes
PHYSICAL
Shipping weight (lbs): 37
Shipping Dimensions (HWD/in): 13 x 10 x 23.75
Unit Dimensions (HWD/in): 10.1 x 6.7 x 13.8
Material of construction: Steel
Form factors supported: Tower
Cooling method: Fan
Battery Access: Supports battery access and hot-swap replacement without powering connected equipment off
COMMUNICATIONS
Network monitoring port : Includes 2 built-in monitoring ports, 1 USB and 1 DB9. Each supports on battery, low battery, power restored, AC line voltage, DC battery voltage, load percentage, battery charge current, battery capacity and line frequency status messaging.
|